Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs
1
Sezione di Bologna, Istituto Nazionale di Fisica Nucleare, viale Carlo Berti Pichat 6/2, 40127, Bologna, Italy
2
Museo Storico della Fisica e Centro Studi Enrico Fermi, Via Panisperna 89 A, 10129, Roma, Italy
3
Dipartimento di Fisica e Astronomia “A. Righi”, University of Bologna, viale Carlo Berti Pichat 6/2, 40127, Bologna, Italy
4
Dipartimento di Elettronica e Telecomunicazioni (DET), Politecnico di Torino, Corso Duca degli Abruzzi, 24, 10129, Torino, Italy
5
Fondazione Bruno Kessler, Via Sommarive, 18, 38123, Povo, Italy
6
Sezione di Torino, Istituto Nazionale di Fisica Nucleare, Via Pietro Giuria, 1, 10125, Torino, Italy
7
Sezione di Lecce, Istituto Nazionale di Fisica Nucleare, Via Provinciale per Arnesano, 73100, Lecce, Italy
8
Sede di Bologna, Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), Via dei Mille 21, 40121, Bologna, Italy
9
Dipartimento di Scienza Applicata e Tecnologia (DISAT), Politecnico di Torino, Corso Duca degli Abruzzi, 24, 10129, Torino, Italy
a
This email address is being protected from spambots. You need JavaScript enabled to view it.
b
This email address is being protected from spambots. You need JavaScript enabled to view it.
Received:
13
November
2025
Accepted:
14
March
2026
Published online:
17
April
2026
Abstract
In this paper, the efficiency of direct charged particle detection with different silicon photomultiplier (SiPM) sensors has been measured to be close to 100%. A time resolution of about 20 ps has also been confirmed for sensors with an active area of about 3
3
and a single-cell pitch of area of 40
40 µ
. In addition, the SiPM performance after irradiation, in terms of timing response and dark count rate, has been evaluated for sensors with a 1
1
area, demonstrating that SiPMs can maintain excellent timing capabilities and a low dark count rate when an appropriate threshold is applied to the signal.
© The Author(s) 2026
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.