https://doi.org/10.1140/epjp/s13360-024-05338-1
Regular Article
Towards a 1010 n/s neutron source with kHz repetition rate, few-cycle laser pulses
1
National Laser-Initiated Transmutation Laboratory, University of Szeged, 6720, Szeged, Hungary
2
Dept. of Optics and Quantum Electronics, University of Szeged, 6720, Szeged, Hungary
3
Center for Exotic Nuclear Studies, Institute for Basic Science, 34126, Daejeon, Republic of Korea
4
HUN-REN Institute for Nuclear Research (Atomki), 4026, Debrecen, Hungary
5
ELI ALPS, ELI-HU Non-Profit Ltd, 6728, Szeged, Hungary
6
TAE Technologies Ltd, 92610, Pauling, Foothill Ranch, CA, USA
7
Ecole Polytechnique, 91128, Palaiseau Cedex, France
Received:
2
April
2024
Accepted:
1
June
2024
Published online:
2
July
2024
A project has been launched for the development of a laser-based neutron source with the few-cycle lasers available at ELI ALPS. Here we show the first experiments, when deuterons were accelerated from ultrathin deuterated foils at 1 Hz repetition rate with the use of 12 fs, 21 mJ laser pulses. The energy spectra of the accelerated deuterons were measured with Thomson ion spectrometers both in forward and backward directions. The accelerated deuterons induced 2H + 2H fusion reaction in a deuterated polyethylene disk. The resulting fast neutrons were measured with a time-of-flight (ToF) detector system, within which each detector consisted of a plastic scintillator and a photomultiplier, at four different angles relative to the normal of the neutron converter disk. We found good agreement with the simulated angular distribution and energy spectra. Here, we also present preparations for the next phases when the repetition rate is increased to 10 Hz. The developed flat liquid jet was demonstrated to accelerate protons over 0.6 MeV cutoff energy with a stability better than 4% for 15 min. We developed two further neutron measurement techniques: a liquid scintillator, the ToF signal of which was evaluated with the pulse shape discrimination method, and a bubble detector spectrometer calibrated against a conventional PuBe source. One of the first upcoming applications is the irradiation of zebrafish embryos with laser-generated ultrashort bunch neutrons. As this experiment needs to be implemented in vacuum, the steps of careful preparation and calibration measurements are also discussed.
© The Author(s) 2024
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.